• Electrical Grade Insulating Crepe Paper / Tubes for Transformer
  • Electrical Grade Insulating Crepe Paper / Tubes for Transformer
  • Electrical Grade Insulating Crepe Paper / Tubes for Transformer
  • Electrical Grade Insulating Crepe Paper / Tubes for Transformer
  • Electrical Grade Insulating Crepe Paper / Tubes for Transformer
  • Electrical Grade Insulating Crepe Paper / Tubes for Transformer

Electrical Grade Insulating Crepe Paper / Tubes for Transformer

Application: Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Motor, Electrical Insulation Crepe Paper Tube for Oil -T
Type: Crepe Paper Tube for Transformer Bushing Electrica
Chemistry: Inorganic Insulation
Material: Insulation Paper
Thermal Rating: A 105
Maximum Voltage: >100KV
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Electrical crepe paper tube
Classification
Inorganic Insulation Material
Certification
ISO9001
Color
Natural or Light Brown, Brown
Brand
Xincheng
Product Name
Kraft Paper Tube
Inner Diameter
3mm~50mm
Thickness of Raw Material
0.05mm, 0.075mm, 0.08mm, 0.13mm
Insulation Class
a (105-ºC)
Place of Origin
China (Mainland)
IEC Standard
IEC-60554
Use
Crepe Paper Rolls Electrical Insulation Crepe Pape
Transport Package
Wooden Case
Specification
2000mm length
Trademark
xincheng
Origin
China
HS Code
482300000
Production Capacity
50000pieces/Day

Product Description

Specifications
Application: Electrical insulation crepe paper tube for Oil -Transformer
Place of Origin: China (Mainland)                                                                Brand Name: XINCHENG
Product name: kraft paper tube                                                                   Material: INSULATION PAPER
Construction: 4-20 layers                                                                            Insulation class: A (105- ºC )
Length: 1000 -- 2000 mm or customized                                                     Color: Natural or Light brown
Breakdown in Oil: 26.2-104.0KV                                                                 Wrinkling: ≥50% or customized
OEM, ODM service:  Avaliable                                                                    Sample: Free
Inner Diameter: 3~50mm                                                                             Outer Diameter: 8~54mm
Thickness of raw material: 0.05mm , 0.075mm,0.08mm,0.13mm
IEC Standard: IEC-60554                                                                             Material: wood pulp
Tensile Strength: 10.4Mpa as product                                                          Package: wooden case
 
Product Introduction:
       Insulation Crepe Paper is one of the most important solid insulation materials used in transformers. Its quality directly influences the life span of the transformer. The BDV is enhanced by up to 80% as compared to base kraft paper. To ensure of best quality of Crepe paper, the base kraft paper is manufactured using longer fibers of pure wood pulp.
      Standard base paper thickness: 0.05mm,0.075mm, 0.08mm & 0.13mm

Made of electrical grade insulation crepe kraft paper, these tubes are used as sleeves for interconnection of terminals, and well used in the oil-type transformers with higher rate of absorption of oil to ensure higher dielectric strength compared to conventional SRBP tubes. They can be bent under extreme conditions without collapsing. Different inner diameter and outer diameter can be offered by customers' requirement.
     Standard length is 1100 mm.
 
Product Description
1. Composition: Crepe tubes made from 100% electrical kraft paper 100% using non ionized water during crepe process to maintain electric properties. Special adhesive is used which it has a good resistance to oil transformer.
2. Properties: High flexibility. High turn capability.
No stress when tube is stretched.
No contamination of oil transformer is guaranteed.
3. Application: special application for oil transformers.

4. Our advantage
      We can offer 1.8m and 2.0m length of this product, which overcame the inconsistency in diameter and easy wrinkling caused by over-length,  we can provide crepe paper tubes with various specifications from 4mm inner diameter.
   Our crepe paper tubes made by fully-automatic machine, it can never be achieved by manual and semi-automatic machines. With the same inner and outer diameters, and according to transformer design principle, more turns creates higher insulativity and tighter winding which contributes to higher elasticity, flexibility, and stronger resistance to bending. So it is possible to product crepe paper tube with the same specification and the same size. The quality of the finished crepe paper tube made by manual weighs only about half the weight of that made fully-automatically because of small volumes of loose layers and the flexibility and intensity is very low.

4.Avalaibility:
Standard crepe tube dimension:
- Inside diameter: since 3mm to 50 mm
- Thickness wall : since 0.8mm to 3,0mm
- Nominal Length: 1800mm, 2000mm,1000 mm as standard 
Other type can be delivered under special order
, such as below:
Inner / outer diameter and can produce other specification as per client request.
4*6mm,4*8mm,6*9mm,7*8mm,7*9mm,7*10mm,8*10mm,10*12mm,11*12mm,11*13mm,11*14mm,12*16mm,13*14mm,13*16mm,14*16mm,14*17mm,16*19mm,18*21mm,20*25mm,34*38mm,46*50mm,68*72mm,etc.
 
Technical data
 
Item
 
Unit
 Thickness of raw material                                          
0.05mm 0.075mm 0.08mm 0.13mm
Thickness of crepe paper mm 0.35±0.05 0.48±0.08 0.80.60±0.08 0.80±0.10
Ash content % ≤ 0.7 ≤ 0.7 ≤ 1.0 ≤ 1.0
Moisture % 6.0-9.0
Diethyl ether % ≤0.3 ≤0.3 ≤0.4 ≤0.5
Water extract PH value   6.0-8.0
Polluted oil % ≤0.1
 
 Tensile strength
MD KN/M ≥1.96 ≥2.6 ≥3.0 ≥3.3
TD KN/M ≥1.3 ≥1.96 ≥2.3 ≥2.7
Wrinkling % ≥ 50
Breakdown voltage V/layer ≥950 ≥1000 ≥1000 ≥1000
Electric conductivity ms/m ≤8.0 ≤8.0 ≤9.0 ≤10.0
 
 
Technical parameter:
No. Index Name Unit Index
1 Wrinkle Number a /10mm Long Number Required In Code
2 Oil Suction Height Portrait mm/10min ≥7
mm/60min ≥30
Transverse mm/10min ≥20
mm/60min ≥50
3 Water Content % ≤8
4 Ash Content % ≤1
5 Conductivity Of Aqueous Extract Ms/m ≤10
6 Ph Of Aqueous Extract - 6-8
7 Electrical Strength Mv/m ≥20
 
 
Packaging & Delivery
Packaging Details
1. Packed with plastic bag first, then put into cartons, finally palletized. 
2. Size of pallet is around 1100x1900x2200mm for 1.8m length tube.

Delivery Time : Around 2-4weeks
 
 
FAQ
Q 1. Are you manufacturer or trading company? Where and when founded?
A: The joint of manufactuer and trading company, who is founded in 2012 and located in TIANJIN City, China.
 Q 2. What is the payment term of your company?
A: TT, L/C for large order; Western union, is also acceptable for small order.
 Q 3. Can you guarantee the quality is the same as that of sample when mass production?
A: Sure. Preshipment sample can be sent, or any kind of inspection is acceptable.
 Q 4. What certificate you have?
A: ISO9000 or other test report can be provided if clients' require.
 Q 5. How long is the sample making time? And how can we get?
A: Within 7 days for lab making. Free sample within 1kg can be provided on customer's international express courier.
 
 
Please Contact Us
Miss: lydia
Mob: 86-13752439076      Fax: 86-22-60863016        
http://chinainsulation.en.made-in-china.com
 
 
 
 
Electrical Grade Insulating Crepe Paper / Tubes for Transformer


Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer
Electrical Grade Insulating Crepe Paper / Tubes for Transformer


 


 

Send your message to this supplier

*From:
*To:
avatar Miss Lydia
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now