Application: Insulators, High Voltage Live Operation, Power System Operatio, Power Transmission
Type: Insulation Rod, Screw-Type Coupling, Insulation Sleeve
Chemistry: Hybrid Insulation
Material: Epoxy Resin FRP, Fiberglass
Thermal Rating: H 180
Maximum Voltage: >100KV
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
High quality wholesale HV Operation High Voltage H
Classification
Inorganic Insulation Material
Certification
UL, ISO9001
Color
Yellow
Brand
Xincheng
Product Name
Fiberglass Insulated Telescopic Operating Rod Hot
Rated Voltage
10kv, 35kv, 110kv, 220kv, 330kv. 500kv, 1000kv
Tensile Strength
10.4MPa
Size
Customers Request
Length
3-14m, Can Be Made as Per Request
Temperature
-25~55
Insulation Body Part
FRP Tube
Applied Standard
IEC60855.
OEM
Accepted
Warranty
More Than 5 Years
Transport Package
Pallet
Specification
PIECE
Trademark
XINCHENG
Origin
China
Production Capacity
100000 Set/Sets Per Month

Product Description

Overview
Quick Details
Place of Origin: China (Mainland)                                                           Brand Name: XINCHENG
Type: insulation rod, Screw-type coupling                                              Usage: Insulation Protection
Product name: Fiberglass Insulated Telescopic Operating Rod Hot Stick Link Stick, insulating hot stick
Name: High Voltage Fiberglass Operating Rod                                     Material: Epoxy resin FRP
Application: High voltage live operation, Power system operation
Rated Voltage: 10-1000kV
Tensile Strength: 10.4Mpa                                                                      Size: Customers Request
length: 3-14m, or can be made as per request                                       Surface: Smooth and beautiful
Insulation body part: FRP tube                                                               Temperature: -25~55
Color:  safety yellow , orange  or Customized.                                       Sample: free samples are available
Supply Ability: 100000 Set/Sets per Month                                            OEM: Accepted
Standard: IEC 60855 and ASTM F711 standard.                                    Warranty: More than 5 Years
Quality Control:  ISO 9001 and 6S qualified
After-sale Service: Online Technical Support, Onsite Inspection
 
product overview:
Insulating lever is an insulating tool used to operate live equipment for a short time, such as switching on or off high voltage isolating switch, falling fuse, etc. This product is made of high quality epoxy resin pipe with excellent insulation performance and mechanical strength, light weight and moisture-proof treatment. It has the characteristics of light weight, high mechanical strength and easy to carry, etc. The handshake part adopts silicone rubber sheath and silicone rubber umbrella skirt bonding, insulating, safe and reliable end metal joint adopts embedded structure more firm, safe and reliable.
Products in line with IEC60855 standard
Insulated operating pole is a unified term for the composition of insulating tools used in power system. It can be used for live operation, live maintenance and live maintenance. Insulated operating pole high voltage tie brake pole (also known as insulated operating pole, insulated pole, high voltage operating pole, commonly known as multi-purpose Link rod) can be divided into 10 KV, 35 KV, 110 KV, 220 KV, 330 KV, 500 KV ,1000KV according to the voltage level. It is an applicable product developed according to the needs of production, operation and maintenance of power system.
The high-voltage gate rod, also known as the Lingke rod, the insulated rod, and the insulated gate rod, is composed of a working head, an insulating rod and a handle. It is used when closing or opening the high-voltage isolating switch, assembling and disassembling the portable ground wire, as well as when measuring and testing. The high-pressure gate rods can be divided into two types according to the combination form, one is the interface type gate rod and the other is the telescopic gate rod. The interface type is relatively durable, and the telescopic type is relatively convenient to operate.
    According to the use environment, it can be divided into two types: one is the ordinary gate rod, and the other is the rainproof gate rod.
    According to the material, it is divided into: glass brake lever, phenolic resin lever, epoxy resin and so on.
 
Product Usage :
The function of the insulated gate rod is one of the commonly used safety tools in the operation of electrical equipment to the gate. It is mainly used for short-time insulation tools for operating live equipment, such as turning on or off high-voltage isolating switches and dropping fuse sets, assembling and disassembling portable grounding wires, and for measuring and testing.
(1) Classic "U", "T", and square heads can be selected. Chrome-plated hooks are easy to use and durable.
(2) It is pultruded with epoxy resin FRP and has strong insulation and high safety.
(3) The chrome-plated interface is stable and does not rust.
(4) Insulating rubber material can effectively prevent electric shock.
 
Application:
Manufacturing technology of high-pressure operating rod This series of operating rods (also known as Link rod) are made of glass fiber cloth, epoxy resin and 306 resin phthalic anhydride, glass fiber cloth and curing agent, and are extruded by drawing machine, forming at one time. Then it is painted and made into other FRP products with beautiful appearance, light structure, easy operation, mechanical and electrical properties, suitable for use under various high voltage conditions, good insulation performance and safe use. The detection period is one year. Inspection basis of high-voltage operating pole: DL408-91 "Electrical Safety Work Regulations" appearance inspection: smooth insulation surface, no bubbles, wrinkles or cracks; good bonding between glass fiber and resin; hollow pipe end with plugs, strong connection between the knuckles and poles.
Fiberglass hot stick is mainly used for splitting high and low voltage switches, pull-in electric brakes and for live working wire clamps. According to the voltage level, it can be divided into 10KV insulated operating rod, 35KV insulated operating rod, 110KV insulated operating rod, 220KV insulated operating rod, 330KV insulated operating rod, 500KV insulated operating rod, 750KV insulated operating rod, 1000KV insulated operating rod etc.
 
High-voltage pull brake rod, Link rod, Operating rod, Operating rod, Rain-proof Link rod, Telescopic pull brake rod, FRP insulating rod, Insulating rod, Insulating pull brake rod
Classification of high-pressure operating rods: 10 kV high-pressure operating rod, 35 kV high-pressure operating rod, 110 kV high-pressure operating rod, 220 kV high-pressure operating rod, 500 kV high-pressure operating rod, 3-meter high-pressure operating rod, 4-meter high-pressure operating rod, 5-meter high-pressure operating rod, 6-meter high-pressure operating rod, 7-meter high-pressure operating rod, 8-meter high-pressure operating rod, 9-meter high-pressure operating rod, 10-meter high-pressure operating rod, 11-meter high-pressure operating rod Operating lever, etc. can be customized.
Main technical parameters: 10 kV voltage is suitable for three four-meter-long operating poles, 35 kV voltage is suitable for three four-meter-long operating poles, 110 kV voltage is suitable for four-section 4.5-meter-long operating poles, 220 kV voltage is suitable for four-section 6-meter-long operating poles, 500 kV voltage is suitable for four-section 8-meter-long operating poles, and can also be customized according to user's specifications.
Composition of high-pressure operating rod: Connecting type: FRP epoxy resin rod, branded connecting rod, rivet, etc. Connection rain-proof type: FRP epoxy resin rod, branded connection button, rivet, insulator
Technical Standards for High Pressure Operating Rod: Environmental Conditions for Use of High Pressure Operating Rod (1) Environmental Temperature: -25 ~55 ~2) Relative Temperature: <90% (3) Use Situations: Rainless Weather indoors and outdoors
 
 
Structure performance:
Brake lever is an insulating tool used to operate live equipment for a short time, such as connecting or disconnecting high voltage disconnecting switch, falling fuse, etc.
1. Interface type insulation lever is a kind of insulation lever in common use. The section adopts the butt screw interface, the length can be up to 10 meters, and the section can be bagged and carried easily.
2. This series of XINCHENG brake lever (insulation operating rod, link rod) is made of the first-class epoxy resin pipe with excellent insulation performance and mechanical strength, light weight, and anti-North Korea treatment. It has the characteristics of light weight, high mechanical strength and easy to carry.
3. The brake lever (insulated operation bar, Link bar) design novel, superior materials, reasonable structure, easy to use.
(1) The brake lever handshake part adopts silicone rubber sheath and silicone rubber umbrella skirt bonding, insulating performance, safe and reliable.
(2) The brake rod end all belong to the joint using embedded or outsourced structure is more firm, safe and reliable.
(3) The brake rod extension and connection is convenient, strong selectivity, various connection forms, can be combined flexibly.
 
Character:
1.Material:Light Epoxy Resin 
2.Light weight, only 2.75kg/m 
3.High voltage 
4. high strength 
5.Anti-moisture. Foam filled tube and ventilated bottom design.
6.Anit-slip . Holding part is roughness treated.
7.Convenience and flexible locking system.
8.Absorbing and anti-friction surface.
9.100% electrical performance tested.
10.Offer special design.
11.Fluorescent green tip section is highly visible and has a form core;
12.Several models and lengths available
13.The stick metal head shape can be customized!
 
TYPE:
Rain proof , Nocturnal overhaul/Night maintenance operation , Interface type brake rod , Telescopic Hv Brake Pull-rod High Voltage Frp Insulation Operating Rod,  Insulator Rain-proof Brake Bar, telescopic pull brake rod, button pull brake rod, gun grounding rod
The insulating rod (Link rod) is made of high quality epoxy FRP pipe with excellent insulation performance and mechanical strength, light weight and moisture-proof treatment. Rain-proof pull brake rod (insulation operating rod) is designed for outdoor rainy days. Rain-proof skirt uses silicone rubber to prevent rain and increase the insulation strength in rainy days. Single rain-proof operating rod; multi-rain-proof operating rod; single rain-proof pull-brake rod; multi-rain-proof pull-brake rod. 2. SA-1 series insulated operating rod (Link rod) has novel structure, advanced and reasonable. (1) The handshake part of the operating pole is bonded with silicone rubber sheath and silicone rubber umbrella skirt, which has good insulation performance and is safe and reliable. (2) The metal joint at the end of the operating rod adopts the embedded structure, which is more firm, safe and reliable. (3) The expansion connection of insulated operating rod is convenient, selective and various, and it can be combined flexibly. For example, SA-A-35/1.2*4 of Link Bar represents 35KV, T-head, 4 segments of insulating rod are 1.2 meters per segment, and threaded connection is used. The index of Link Bar Operator (T-type, L-type, H-type), number of insulating rod nodes (3, 4, 5) and connection mode of insulating rod (A, S) are as follows: Link Bar SA-A-35/1.2*4 represents 35KV, T-type head, Namely: 4 knots and 6 meters. In addition, accept customization.
 
   Specifications:
Type Withstand Voltage
(kV)
Insulating Length
(mm)
Total Length
(mm)
Section
XC-1 10 700 3000 3
XC-2 35 900 4500 3-4
XC-3 66 1000 4500 3-4
XC-4 110 1300 5000 3-4
XC-5 220 2100 5000 3-4
XC-6 330 3100 5000 4-5
XC-7 500 4000 8000-10000 4-5
XC-8 750 5000 10000-14000 6-7
XC-9 1000 7000 140000 7
 Notes:
1.Please check out whether the appearances of the operating lever is smooth and has no scratch, whether
the hollow tube is blocked up and whether the segments are connected firmly.
 2.Please check out the power-frequency withstand voltage test date. The products must carry out regular
 tests strictly according to DL408-1991 Working Regulation of Power Safety. If the products' test date is over the
expiry date, don't uses them after you have test them strictly.
 3.Please check out carefully whether the label of the high voltage brake pull-rod is clear and whether the name
of the manufacturer, manufacturing date, fitted rated voltage are accurate and complete.
 4.Please pay special attention to moisture proof to ensure the accuracy of  the electrical properties and mechanical properties.
 
Summary of usage items
(1) Before using the insulated operating rod, check whether the model specification,
manufacturer name, manufacturing date, voltage level, and (double triangle) symbols for live work are clear and complete.
(2) The insulated part of the insulated operating rod should be free from bubbles, wrinkles, cracks, shedding of the insulating
layer, severe mechanical or electric burn marks, and the glass fiber cloth and resin should be well bonded and no glue.
(3) The sheath of the hand held part of the handshake and the operating rod should be connected tightly, without damage, and
without relative sliding or rotation.
(4) Before operation, wipe the surface of the insulated operating rod with a clean dry cloth to make the surface dry and clean.
(5) During operation, the human body should keep a sufficient safe distance from live equipment.
(6) The operator's hand grip should not go over the guard ring to maintain an effective insulation length, and take care to
prevent the insulated operating rod from being shorted by the human body or equipment.
(7) In order to prevent large leakage currents due to dampness and endanger the safety of operators, insulating gloves should be
worn when using insulated operating rods to pull switches or disconnecting switches and circuit breakers through a transmission
mechanism.
(8) When operating electrical equipment outdoors in rainy weather, the insulated part of the insulated operating rod should have a
rain cover, and the upper mouth of the cover should be tightly integrated with the insulated part, without leakage, so as to block
the rainwater flowing down and prevent it from forming The connected water flow column greatly reduces the wet flash voltage.
(9) When using an insulated operating rod to operate outdoor high-voltage equipment in rainy weather, insulated boots should be
worn.
(10) The insulated operating rod should be subjected to a manual withstand voltage test once a year, and those who fail to pass
are strictly prohibited to use it.
 
FAQ
1 How long is your products warranty ?
A: The warranty period of our products is 18 months.
2 How about inspection?
A: We have the whole inspection system from raw material to end products include temperature test, strength test and so on.
3 What do you have for certificate?
A: Our products are passed through IEC60947and IEC60269standarded.
4 What is payment terms?
A: T.T, Western Union and L/C is acceptable.
5 What is the service offered by company?
A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.
We also have the sales team to offer good service from pre-sale to after-sale.


Our service:
 1.  Our sales representative are 24 hours online, to ensure reply you ASAP.
 2.  When the products are finished, they must be checked by our QC firstly.
 3.  We own several whole production lines, which can not only provide best quality and competitive price, but also reduce production period.
 4.  Urgent Orders can provide overtime production.
 5.  We can support OEM & ODM, and can be customized according to the detailed requirement, Like samples or sketches. 
 
 
Packaging & Delivery
Packaging Details:
suitable packing for export. Economic Packing design which will save your transportation cost.
1.Inside packing: Anti-moisture nylon bag + Carton box + woven belt.
2.Outside packing: carton box or wooden case and pallet.
3.According customer requirement.
Port: Shanghai, Qingdao, Tianjin
Lead Time : 7-15days
 
 
Please Contact Us
 Miss: lydia
Mob: 86-13752439076      Fax: 86-22-60863016        
 
 
 
High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod

 High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod
 
High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod

High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod

High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod
High Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull RodHigh Quality Wholesale Hv Operation High Voltage Hot Stick Fiberglass Pull Rod










 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now