Grounding Wire for Grounding Rod (strip line) Cable Branch Box

Product Details
Customization: Available
Usage: Working Earthing, Earthing System, Lightning Protection Earthing, Protection Earthin
Working Voltage: High Voltage
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
101~500 square meters
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
  • Grounding Wire for Grounding Rod (strip line) Cable Branch Box
Find Similar Products

Basic Info.

Model NO.
Grounding wire for grounding rod (strip line) cabl
Application
for Grounding of Cable Branch Box or Ring Main Uni, High Voltage Transmission Line
Earthing Method
Direct Earthing Method
Material
Galvanized Aluminum
Certification
CCC, ISO9001, ROHS
Size
Meidum
Brand
Xincheng
Product Name
Removable Cable Branch Box Multi-Purpose Ring Main
Scope of Use
Grounding of Cable Branch Box or Ring Main Unit (R
Constitute
Grounding Rod, Grounding Clamp, Removable Copper H
Rated Voltage
10kv
Kind
1 or 3 Phrases as Customized
The Material Operating Rod
Super Epoxy Non-Alkali Fiberglass Fabric Tube
Package
Aluminum Alloy Fireproof Portable Box.
Transport Package
Pallet
Specification
SET
Trademark
XINCHENG
Origin
China

Product Description

Quick Details:
Place of Origin: China (Mainland)                                              Brand Name: XINCHENG
Product name: Removable cable branch box multi-purpose Ring Main Unit (RMU) grounding wire
Scope of use: Grounding of cable branch box or Ring Main Unit (RMU)           
Constitute: Grounding rod, grounding clamp, removable copper head, multi-specification copper head, copper pin head
Application: For grounding of cable branch box or Ring Main Unit(RMU)
Characteristics: Temporary Grounding equipment
Rated Voltage: 10KV                                                               Kind: 1 or 3 phrases as customized         
Cooper wire's cross section area: 25 mm² / 35mm² /50 mm² /75mm²/90mm²/95mm²/120mm²/130mm²/150mm²; or customized.
The temperature scope for protective cover: -25+55°C.           
Grounding flexible copper wire standard: length and wire diameter can be customized according to user needs.
The material of clamps: Aluminum/copper                            Strength: >=600N/mm2
Standard of electric clamp: opening distance of electric clamp 35mm
The material operating rod: Super Epoxy Non-alkali Fiberglass Fabric Tube
Rod length: 0.5m, 1m, 1.5m or customized.                         Color: Red, green, yellow or or as per your requires 
Package: aluminum alloy fireproof portable box.                 Ground operating rod: IEC60855:1985.  IEC61230:2008.
Grounding Wire for Grounding Rod (strip line) Cable Branch Box

Product introduction:
The grounding wire of the cable branch box is easy to install and flexible in incoming and outgoing lines. Generally, there are 6 to 8 branch incoming and outgoing lines in use, which can realize multiple power transmission in the community, providing technical guarantee for deepening the load center, shortening the power supply radius and reducing the line loss. At the same time, the cable branch box can be equipped with power indicator, fault indicator, silicone rubber fully insulated plug-in lightning arrester, mechanical programmable lock, grounding switch, etc. to ensure the safety of operation, maintenance and management. Cooperating with cable looped power supply, SF6 and other looped load switches can be configured to meet local outage maintenance requirements, realize regional outage maintenance and reduce outage scope without affecting the operation of the main network. At the same time, the loop-network cable branch box can realize the loop-network power supply, laying a foundation for the future adjustment of the 10 kV line network structure.
There are many kinds of 10 kV outdoor cable branch boxes, so the installation and construction of 10 kV cable branch box becomes important. Whether the operation method of the installation and connection process of the cable branch box and cable connector is correct, whether the installation process of the cable head is familiar, the sequence of the assembly of the internal components of the cable branch box and the cable connector components, and whether the operation is carried out according to the installation specifications provided by the manufacturer will directly affect the service life and normal operation of the cable branch box.
The grounding wire of high-voltage portable cable branch box shall be selected with appropriate nut models, which can be divided into 12 #, 13 #, 14 #, 15 # and 16 # models and three standard ring main cabinet contact pins. Generally, 12 #, 14 # and 16 # models are mostly used.
Grounding Wire for Grounding Rod (strip line) Cable Branch Box

Texture of material:

The material of the grounding rod is: glass fiber reinforced epoxy resin, the connector is all brass, and the grounding clamp is aluminum (copper grounding clamp can be customized). Line length is generally 3 * 1+1.5 meters (25 mm2)
Packaging: aluminum alloy fireproof portable box.
Applicable environment: Ring Main Unit(RMU)/cable branch box
Before the operation of the grounding wire of the cable branch box, check whether the grounding wire of each branch cable is firmly connected with the grounding terminal of the box. At the same time, the box shell must be directly connected to the grounding grid or have an obvious grounding point. After the installation of the grounding wire of the cable branch box, the components of the cable must be tested together in accordance with the relevant test standards and conditions.
Product parameters: 1 insulating rod (or 3) with a length of 0.5 m, 1 copper wire with a length of 3 * 1+3 m, 25 square meters, 3 detachable copper connectors, 15 copper connectors (3 for each of 10, 12, 14, 16 and 18 mm), 3 copper pins (12 mm in diameter and 185 mm in length), and 1 aluminum grounding wire clamp. The grounding rod (wire) of the cable branch box is made of multi-strand high-quality flexible copper wire, and is covered with a soft, high-temperature resistant transparent insulating sheath.
Grounding Wire for Grounding Rod (strip line) Cable Branch BoxGrounding Wire for Grounding Rod (strip line) Cable Branch BoxGrounding Wire for Grounding Rod (strip line) Cable Branch BoxGrounding Wire for Grounding Rod (strip line) Cable Branch Box

Note: This specification is recommended. If it does not meet customer requirements, it can be customized according to customer requirements. The following parameters are required for customized grounding wire:
1. Operating voltage;
2. The length of the grounding rod and the style of the grounding terminal;
3. Sectional area, length and connection mode of copper wire (split phase or closed phase);
4. Grounding terminal style (spiral clamp or ground stud).

Portable short circuit grounding wire can be divided into split phase grounding wire and closed phase grounding wire. There are single-section and multi-section operating rods with different voltages. Short-circuit grounding wires are used for power transformation and transmission lines.
Grounding Wire for Grounding Rod (strip line) Cable Branch BoxGrounding Wire for Grounding Rod (strip line) Cable Branch BoxGrounding Wire for Grounding Rod (strip line) Cable Branch Box
Structural characteristics of grounding wire of branch box:
1. The insulating rod is a detachable quick-release structure, which makes the operating rod and the operating head can be separated without affecting the work, and solves the contradiction between the insulating rod being too long and the space of the junction box being too small when conducting the grounding work again.
2. The grounding of the grounding wire of the branch box should be checked before the grounding operation to better ensure the safety of the operators.
3. This product has reasonable structure, tight connection, excellent safety performance, simple operation, and can also be disassembled and carried, saving a lot of manpower and material resources and space.
4. The short circuit wire and grounding wire are made of multi-strand high-quality soft copper wire, and are covered with a soft, high-temperature resistant transparent insulating sheath, which can prevent the wear of the grounding copper wire in use and ensure the safety of operators in operation
5. The connection nose, bus clamp, grounding copper wire and outer sheath adopt a new process of crimping. The soft connection can effectively prevent the broken strand of copper wire at the connection during use, and improve the reliability and service life of the grounding wire.
6. The grounding operating rod is made of advanced epoxy resin and glass fiber with excellent insulation performance and mechanical strength. At the same time, the operating handle is equipped with silicone rubber sheath, which is firmly bonded, and the insulation is more safe and reliable.

The power frequency withstand voltage test of the operating rod, the 10KV, 35KV, 63KV, 110KV and 220KV grounding rod shall pass the withstand voltage test at 45KV, 95KV, 175KV, 220KV and 440KV respectively, and keep it without breakdown for one minute. The 330KV and 500KV grounding rods shall be applied with withstand voltage at 380KV and 580KV respectively. Keep it for five minutes without breakdown.
Grounding wire standard: our company's flexible copper wire is made according to national standards. The resistance to ground is as follows: measure the DC resistance between the lugs. For various sections of 25mm2, 35mm2, 50mm2, 70mm2, 95mm2,120mm2, the average resistance value per meter should be less than 0.79m Ω, 0.56m Ω, 0.40m Ω, 0.28m Ω, 0.21m Ω, 0.16m Ω respectively. The power frequency withstand voltage test of the operating rod, the 10KV, 35KV, 63KV, 110KV and 220KV grounding rod shall pass the withstand voltage test at 45KV, 95KV, 175KV, 220KV and 440KV respectively, and keep it without breakdown for one minute. The 330KV and 500KV grounding rods shall withstand voltage at 380KV and 580KV respectively, and shall not break down for five minutes. The period shall not exceed 5 years.
Grounding Wire for Grounding Rod (strip line) Cable Branch BoxProduct parameters:
Item Pure copper grounding wire Grounding rod Grounding copper head Hexagon connection copper head Copper grounding pin Double-hole grounding clamp Aluminum alloy storage box
1 25 square meters, 3 phases * 1 meter+1 phase * 3 meters 0.5M* 3 PCS Length 95MM (10 #, 12 #,14 #,16 #,18 #)*3PCS 12MM diameter, 170MM length Opening 35MM 740X300X140MM
2 25 square meters, 3 phases * 1 meter+1 phase * 3 meters 0.5M* 1 PCS Length 95MM (10 #, 12 #,14 #,16 #,18 #)*3PCS 12MM diameter, 170MM length Opening 35MM 740X300X140MM
3 25 square meters, 3 phases * 1 meter+1 phase * 3 meters 0.5M* 1 PCS Length 95MM (12 #,14 #,16 #)*3PCS Customizable 12MM diameter, 170MM length Opening 35MM 740X300X140MM
Grounding Wire for Grounding Rod (strip line) Cable Branch Box
Selection of short-circuit grounding wire:
The selection of portable short circuit grounding wire shall be able to withstand the large short circuit current of the suspension point, and its rated short circuit current value shall not be less than the large fault current of the suspension point. When the reclosing is not released, the impact of the secondary short-circuit current impact on the rated short-circuit current value of the short-circuit grounding wire should also be considered.
The length of the short circuit grounding wire shall be suitable for the size of the equipment and the distance from the fixed grounding point. The product value of the rated short circuit current square and the rated time shall not be less than the product value of the fault current square and the fault time. If the length of the grounding wire is less than 1.2 times the distance from the connection point, it may cause more serious stress than that in the type test. If it is too long, the residual voltage at the working point will be too high and the grounding wire will swing strongly during short circuit.
Grounding Wire for Grounding Rod (strip line) Cable Branch Box
Maintenance and storage of grounding rod (wire) of cable branch box:
Before each use, carefully check whether the grounding wire is in good condition. The flexible plastic copper wire shall be free from exposure, broken ends and loose nuts. Otherwise, it shall not be used. The product shall be kept clean and tidy, and shall not be thrown everywhere. Attention shall be paid to the cleaning and hygiene work to prevent sediment and dirt from entering the pores of the product, thus affecting the normal use of the grounding wire. The grounding wire subjected to short circuit current shall be judged according to the size and appearance of the short circuit current, and shall generally be scrapped.
Before using portable short circuit grounding wire, check the power supply to confirm that the power has been cut off, and then confirm that there is no voltage on the equipment. First connect the grounding wire clamp to the grounding grid or flat iron piece, and then use the grounding rod to screw the wire end on the equipment wire. When removing the short circuit grounding wire, the sequence is exactly the reverse of the above.
Portable short circuit grounding wire shall be properly kept. Before each use, carefully check whether it is in good condition, the soft copper wire is not exposed, and the nut is not loose, otherwise it cannot be used.
The inspection cycle of portable short circuit grounding wire is once every five years, and the inspection items are the same as the factory inspection. After passing the test, the portable short circuit grounding wire shall be judged according to the size of the short circuit current and the appearance inspection, and shall generally be scrapped.
Copper wire is made of electrolytic copper high-quality material.

FAQ:
  Q 1, Could you accept the sample order and if it is free ?
 A Yes, we welcome the sample order to test and check quality. And the sample and the delivery fee are not free.
  Q 2, How do you ship the goods and how long does it take to arrive?
 A The sample is usually transported by DHL, Fedex, UPS or TNT express. We will choose the economical express and transport way according to the goods quantity, or as the requirements of client's . The express time is usually around 3-7 working days.
  Q 3, Do you provide the customized service and OEM?
 A Yes, it is available.
  Q 4, How about the after sale service?
 A Any questions, pls contact us freely! We will service you well ! 
Our supply ability: 250,000 Piece/Pieces per Month, More specific u can understand us through email.

Our Services:
We are specialized in power and cable equipment and construction tools. According to customers' need, we can provide the most suitable products and solutions. Ensuring the quality of products, we organize production and make delivery in time, solve the guests' needs and problems perfectly.

Packaging & Delivery:
Packaging Details: 
suitable packing for export. Economic Packing design which will save your transportation cost, or as customer requirements
1.Inside packing: Anti-moisture nylon bag + Carton box + woven belt. 
2.Outside packing: carton box or wooden case and pallet. 
3.According customer requirement.
Port: Shanghai, Qingdao, Tianjin
Lead Time : 7-15days

Please Contact Us:
 Miss: lydia
Mob: 86-13752439076      Fax: 86-22-60863016        
 
 
 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier